Abstract
A laser three-dimensional (3D) projection system is an auxiliary system in intelligent manufacturing. It works with a positioning system in practical applications. This study proposes a calibration method for laser 3D projection systems based on binocular vision. The significance of the binocular vision positioning function for the calibration process was analyzed. Two calibration methods for laser 3D projection systems based on the binocular vision positioning function were proposed. One method involves simplified calculation models and another used data to solve the conversion relationship. The experimental calibration of the projection system was performed using data to directly solve the conversion relationship. The experiment demonstrated the simplicity of the proposed calibration method. The calculation time was less under the 3D laser projection system based on binocular vision. Moreover, the mean calibration error was 0.38 mm at a working distance of 1.8-2.2 m.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.