Abstract

Background and objectiveThe identification of motor intention by analyzing electroencephalogram (EEG) signals has become an important issue in brain-computer interface (BCI) applications. Since the individual differences of EEG are large, it’s hard to design a universal BCI system, which means the labeled data from current user have to be collected for calibration. We propose a multi-source fusion transfer learning algorithm for this calibration, which only needs a small amount of new data from the current user. MethodsThe core idea of proposed algorithm is a two-step calibration based on transfer learning, which works on the levels of both subjects and features. The spatial covariance matrices represented in the Riemannian space are used to characterize the multi-channel EEG signals. Source subjects whose features are similar to the current user are selected as the transfer source via a Riemannian geometry alignment algorithm. Their features obtained from the Riemannian tangent space, as well as the ones of the current user, are fused and calibrated by a balanced distribution adaptation algorithm. Finally, a classification model could be trained for the current user with only a few new training data. ResultsValidated on both the online ERD-BCI database and the BCI Competition IV 2a database for motor imagery tasks, experimental results show that our method outperforms the state-of-the-art methods. When the new training data from current user is insufficient, the classification accuracy and kappa values compared with the outstanding counterparts have advantages of 3.30 % and 0.05 respectively on the online ERD-BCI database, 3.95 % and 0.03 respectively on the BCI Competition IV 2a database. Even when the new training data from current user is sufficient, the classification accuracy and kappa values of our proposed method also outperforms the counterparts with highest performance by 2.37 % and 0.05 respectively on the online ERD-BCI database, 2.25 % and 0.03 respectively on the BCI Competition IV 2a database. ConclusionsThe algorithm provides a new idea of solution for calibrating EEG features. It is expected to contribute to the practical applications of BCI.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.