Abstract

A passive higher harmonic cavity (HHC) will be used in the Hefei Light Source II Project (HLS- II) to lengthen the bunch and consequently increase the beam lifetime dominated by Touschek scattering. The effects of constant voltage and constant detuning have been calculated and compared over the operating current from 0.4 to 0.2 A on the bunch lengthening for the passive normal conducting harmonic cavity system in HLS- II. The results show that the bunch shape has less change and the lifetime improvement factors are not less than 2.7 over the beam currents for the constant voltage case. The constant voltage operating scheme may be applied to our machine.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.