Abstract

Increasing of tritium concentration in the primary coolant of the research and test reactors during operationhad been reported. To check the source for tritium release into the primary coolant during operation of theJMTR and the JRR-3M, the tritium release from the driver fuels was calculated by MCNP6 and PHITS. Itis clear that the calculated values of tritium release from fuels are as about 107 and 106 Bq for the JMTR andJRR-3M, respectively, and that calculated values are about 4 order of magnitude smaller than that of themeasured values. The JMTR is a tank type, and the JRR-3M is a pool type research reactor. The primarycoolants are light water, in which the coolant temperature is lower than 50ºC. These results show that thetritium release from fuels is negligible for both the reactors. In the calculations of tritium release rates intothe water by PHITS, a gaussian triton energy by ternary fissions of 235U.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.