Abstract

In this paper, we calculate the parameters of the energy complex on liquefied natural gas (LNG), which serves for the gasification of LNG with its further utilization in the circuit of a steam turbine plant, during operation of which additional electrical energy is generated. We evaluate the effectiveness of regasification of cryoproducts and evaluate the potential of using Cold Energy.Various schemes of power plants using Cold Energy are considered. The parameters and characteristics of the combined-cycle plant consisting of the gas-turbine circuit and the steam-turbine circuit are calculated. The coefficient of cryoproduct energy return (liquefied natural gas) of the considered schemes is calculated and and based on the data obtained, the most optimal one is selected.