Abstract
This article discusses application of data acquisition device National Instruments NI PCI-6221 for electrical separator low cost monitoring. Results can be applicable for air protection and air pollution prevention. Measured basic electrical and environmental values are logged into a file. Further the data serve as input for calculation of solid particles trajectory inside the separator. Influence of particular quantities onto the separator operation and particle trajectory calculation is discussed. Theoretical and technical limits of used device for high voltage measurements are explained in the first part. Main part of the paper deals with calculation of the trajectory and implementation in LabVIEW environment. Influence of particular physical parameters is elaborated. Presented ideas are generalized for more complex system in last chapter.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.