Abstract
In order to calculate the parasitic capacitors of a transformer, it is important to apply the correct transformer terminal voltages such that only the desired lumped capacitors are charged. This paper shows the correct transformer terminal voltages that match measurement scenarios that are widely used to extract lumped capacitor values. The parasitic capacitors are calculated based on the stored energy in the transformer windings for different measurement scenarios. A 5kW heavily interleaved high turns-ratio planar transformer is constructed, and its parasitic capacitance is measured. Lumped capacitor simulations are performed using Ansys Maxwell 3D. The simulations are verified through comparison with the measurements and the difference from the measurements is between 1.55-3.76%. The calculation method has a difference of 9.92-10.38% compared to the simulated model, which primarily is caused by an assumption of overlapping turns which is different from the simulated model.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.