Abstract

The spatial pattern of the new type of heating curing building directly affects the energy consumption of the PC component and the passive utilisation efficiency of solar energy. Based on the thermal design theory and building energy consumption simulation analysis method, this study constructed the heating-curing energy consumption model and determined the evaluation index of building space shape parameters. Based on the energy consumption model and Energy Plus simulation software, the calculation case—the best spatial shape characteristic parameters of the new-type heating and curing building in the Shijiazhuang area was given. Compared with the traditional steam warming curing, the carbon emission per unit building area was reduced by 33.4% each year, and the carbon emission of one ton of PC component was reduced by 0.97t.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.