Abstract

Abstract The paper presents the results of calculations performed using the authors′ model to predict the heat transfer coefficient during flow boiling for two refrigerants R134a and R1234yf. The experimental data from various past studies have been collected and the calculations have been conducted for the full range of quality variation and a wide range of mass velocity. The aim of the study was to test the sensitivity of the in-house flow boiling and flow condensation model. The importance of taking into account the surface tension as the parameter exhibiting its importance in case of the flow in minichannels, as well as the influence of the reduced pressure were analysed. The obtained numerical results show good consistency with those recorded in the experiments.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.