Abstract

The exposure rate at the maze-protected door of a therapy room can be computed easily using the concept of gamma -ray albedo and a digital computer, if the exposure rate in the useful beam at some distance, the amount of leakage radiation and the room dimensions are known. The results of computer calculation show attenuation factors of 150-1000 for typical therapy rooms with maze walls and for gamma -ray energies of 200 keV to 1.25 MeV.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.