Abstract
Recirculation (R), the shunting of arterial blood back into to the venous lumen, commonly occurs during veno-venous extracorporeal membrane oxygenation (VV-ECMO) and renders the monitoring of the venous line oxygen saturation no longer reflective of patient mixed venous oxygen saturation (S(V)O(2)). Previously, we failed to prove the hypothesis that, once R is known, it is possible to calculate the S(V)O(2) of a patient on VV-ECMO. We hypothesize that we can calculate S(V)O(2) during VV-ECMO if we account for and add an additional correction factor to our model for dissolved oxygen content. Therefore, the purpose of this study is to derive a more accurate model that will allow clinicians to determine S(V)O(2) during VV-ECMO when ultrasound dilution is being used to quantify R. Using an extracorporeal circuit primed with fresh porcine blood, two stocks of blood were produced; (1) arterial blood (AB), and (2) venous blood (VB). To mimic recirculation, the AB and VB were mixed together in precise ratios using syringes and a stopcock manifold. Six paired stock AB/VB sets were prepared. Two sets were mixed at 20% R increments and 4 sets were mixed at 10% R increments. The partial pressure of oxygen (pO(2) ) and oxygen (O(2)) saturation of the stock blood and resultant mixed blood was determined. The original model was modified by modeling the residual errors with linear regression. When using the original model, as the partial pressure of arterial oxygen (P(a)O( 2)) of the stock AB increased, the calculated S(V)O(2) was higher than actual, especially at higher R levels. An iteration of the original model incorporating the P(a)O(2) level (low, medium, high) and R was derived to fit the data. The original model using R and circuit saturations for the calculation of S(V)O( 2) in VV-ECMO patients is an oversimplification that fails to consider the influence of the high pO(2) of arterial blood during therapy. In the future, further improvements in this model will allow clinicians accurately to calculate S(V)O(2) in conjunction with recirculation measurements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.