Abstract
Introduction CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Materials and Methods Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arrive at CR-39, the calibration factor, and the suitable depth of chemical etching of CR-39 in air and water was calculated. In this simulation, a range of data were obtained from SRIM2008 software. Results Calibration factor of CR-39 in water is calculated as 6.6 (kBq.d/m)/(track/cm) that is corresponding with EPA standard level of Radon concentration in water (10-11 kBq/m). With replacing the skin instead of CR39, the volume affected by Radon and progeny was determined to be 2.51 mm for one m of skin area. The annual dose conversion factor for Radon and progeny was calculated to be between 8.8-58.8 nSv/(Bq.h/m). Conclusion Using the CR-39 for Radon measurement in water can be beneficial. The annual dose conversion factor for Radon and progeny was calculated to be between 8.8-58.8 nSv/ (Bq.h/m).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.