Abstract

The performance of a suite of different carboxylic salts of calcium, have been assessed as dual NO x /SO x reducing agents. The salts studied include, calcium magnesium acetate (CMA), calcium acetate (CA), calcium formate (CF), calcium benzoate (CB), calcium propionate (CP) and magnesium acetate (MA). The primary fuel was propane operating with a primary zone stoichiometry fixed at λ 1=1.05 and the reburn zone stoichiometry, λ 2, was varied between 1.03 and 0.86. Overall stoichiometry, λ 3, was 1.15. CMA was also tested using a US Blend coal as the primary fuel. Experiments were performed in a down-fired pulverised coal furnace operating at an output of 80 kWth. Results showed that CMA and CP were the best dual NO x /SO 2 performers followed by CB, CA, MA and CF. Also, the co-injection of urea with the carboxylic salts as an advanced reburning agent was studied. The results showed that real improvements in NO reduction over basic reburning of greater than 70% could be obtained depending to a large extent on the initial effectiveness of the reburn fuel as well as nitrogen stoichiometric ratio within the reburn zone. Decomposition of the carboxylic salts was studied by thermo-gravimetric analysis (TGA) yielding information on the release of organic fractions important as precursors for CH i radical formation. Examination of structural and thermo-chemical properties of the carboxylic salts identified a correlation of NO reduction under reburning conditions with volatile organic content. Calcium magnesium acetate and calcium propionate showed superior SO 2 capture ability with reductions greater than 70% at Ca/S above 2, around 20% higher than calcium acetate and calcium formate. Magnesium acetate achieved reductions of less than 10% at Mg/S ratios up to 2.5. There is a clear difference in the potential effectiveness of the sorbents as dual NO x /SO 2 reductants, since the organic input for a given Ca input varies according to the composition of the sorbent. Some compromise may have to be made when choosing the correct operating conditions since good reductions in SO 2 may not give acceptable NO x reductions. However, the application of advanced reburning under these conditions has been shown here to compensate for low initial NO x reductions by basic reburning.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.