Abstract
To evaluate the volumetric changes on occlusal surface of computer-aided design and computer-aided manufacturing (CAD-CAM) occlusal devices fabricated following a fully digital workflow after occlusal adjustment, compared to those fabricated with an analog workflow. Eight participants were included in this clinical pilot study, receiving two different occlusal devices fabricated with two different workflows, fully analog and fully digital. Every occlusal device was scanned before and after the occlusal adjustments to compare the volumetric changes using a reverse engineering software program. Moreover, three independent evaluators assessed a semi-quantitative and qualitative comparison using visual analog scale and dichotomous evaluation. The Shapiro-Wilk test was performed to validate normal distribution assumption, and a dependent t-Student test for paired variables was used to determine statistically significant differences (p-value < 0.05). The root mean square value was extracted from the 3-Dimensional (3D) analysis of the occlusal devices. The average values of the root mean square were higher for the analogic technique (0.23 ± 0.10 mm) than the digital technique (0.14 ± 0.07 mm) but the differences were not statistically significant (paired t-Student test; p = 0.106) between the two fabrication techniques. The semiquantitative visual analog scale values between the impression for the digital (5.08 ± 2.4 cm) and analog (3.80 ± 3.3 cm) technique were significant (p < 0.001), and statistically significant differences values were assessed for evaluator 3 compared to the other evaluators (p < 0.05). However, the three evaluators agreed on the qualitative dichotomous evaluation in 62% of the cases, and at least two evaluators agreed in 100% of the evaluations. Occlusal devices fabricated following a fully digital workflow resulted in fewer occlusal adjustments, as they could be a valid alternative to those fabricated following an analog workflow. Fabricated occlusal devices following a fully digital workflow could have some advantages over analog workflow such reduce occlusal adjustments at delivery appointment, which can result in reduced chair time and therefore increased comfort for the patient and clinician.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.]
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.