Abstract

ABSTRACTAn extremely simple and inexpensive apparatus for preparation of the C60 and C70 fullerenes is described. An efficient separatory technique is described which implements a phenylglycine based HFLC column for preparation of high purity (99.99%) C60 and C70 samples. Treatment of C60 with osmium tetroxide and pyridine gives the osmate ester (2:1 adduct) and establishes that oxygen functionality can be added to C60 without disrupting the carbon framework. Raman spectroscopy of high purity C60 indicates that several lines previously not assigned to C60 (D.S.Bethune, G.Meijer, W.C.Tang, and H.J.Rosen, Chem.Phys.Lett.174, 219(1990)) are attributable to C60.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.