The C* (modified J-integral) control creep experiment' system was developed using micro-computer. The system was applied to the C*-constant control creep test of type 304 stainless steel CT specimen at 550°C. The test result showd that the C* was successfully controlled in elevated temperature test with the developed system and the crack growth rate was almost constant under the secondary creep region and C* constant condition.