Abstract

The effects of emergency core coolant (ECC) temperature on the performance of the emergency core cooling system (ECCS) during a loss-of-coolant accident (LOCA) of a boiling water reactor (BWR) were investigated experimentally using the Rig of Safety Assessment (ROSA)-III integral test facility. The ECC temperature had no direct influence on the ECCS core cooling performance, since ECC became nearly saturated before reaching the core irrespective of the initial temperature, however, had indirect effects by changing the vessel pressure response. The ECCS injection timings and flow rates, and the core inlet flooding behavior were affected. The measured peak cladding temperature (PCT) was not affected by the ECC temperature for both large (200%) and small (5%) break tests.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.