Abstract

To report a patient who sustained a spark fire burn during a routine pterygium operation. A 40-year-old woman was referred for pterygium excision in her left eye. During the operation a low temperature cautery caused a spark fire that resulted in left eye corneal burn, upper and lower eyelid burns, and melting of eyelashes and eyebrows bilaterally. Topical antibiotics and vitamin C followed by topical corticosteroids were given. After 1 week the corneal epithelium healed but a paracentral corneal opacity developed. Two months later on last follow-up visit, a mild diffuse corneal opacity was still seen. The combination of three elements found in most routine (ophthalmologic) surgical fields-an enriched oxygen environment with the high temperature transmitted by the electrocautery in the vicinity of hair-might explain the event. Surgeons should try to separate these three elements or eliminate any of them, in order to minimize or prevent such events.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.