Abstract

The bulk modulus of scandia is evaluated by ab initio calculation, based on density functional theory, and compared with bulk modulus measurement on nearly fully dense scandia and with the value attained from the equation of state based on diamond anvil cell measurements. The current results are in the upper range of the bulk moduli results in the literature. The scatter in the literature results might be explained by the differences in the specific volumes of the measured and calculated cases. For the specific volume of 59.65 ± 0.07 Å3 the average measured isothermal bulk modulus of scandia from the present study and recent literature results is 188 ± 10 GPa.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.