An analytical procedure for the bulk analysis of environmental samples, consisting of decomposition of samples, acid digestion of the recovered materials, chemical separation of uranium and plutonium, and isotopic measurements by thermal ionization mass spectrometry and isotope dilution mass spectrometry. The determination of the total amount of uranium contained in four process blanks was performed to verify the reproducibility of the bulk analysis procedure. The analytical results of a simulated environmental sample prepared from certified reference materials met the qualification requirements of the network of analytical laboratories for bulk analysis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.