Abstract
The modelling of placement upon the seismic resistant structure can be carried out separately or directly. Separated modelling refers to the modelling using fixed joint, while direct modelling is defined as the lower structure directly using spring on soil-foundation interaction. Both modelling have differences in the context of behaviour and reaction of structure that must be adjusted based on SNI 1726:2019 and pile needs. This research analysed the calculation of static bearing capacity of pile and manual calculation of k coefficient by Nakazawa method and a supporting program SAP2000 V14.2.5. The analysis results indicated that under the manual calculation, total pile needs on fixed joint modelling of spun pile in diameter 600 mm class B are 185 piles within pile cap modelling at every point of column, meanwhile using SAP2000 V14.2.5, it is obtained the pile needs of spring modelling are 176 piles within integral pile cap modelling. The structural behaviour and the reaction of both modelling demonstrated the values of drift control, period, mass participation, static dynamic shear force, and force output in the fixed joint modelling were less than spring modelling.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.