Abstract
This paper presents an investigation into the effect of area ratio parameter of diffusers on its energy output through power coefficient Cp. This parameter has effect both on diffusers’ energy yield, besides diffuser’s size for architectural integration prospects. A systematic increase in diffusers area ratio is adopted following standardized diffuser profile presented by NACA 1244 aerofoil. A series of area ratios were investigated (i.e., 1.25, 1.5, 1.75, 2, 2.5, 3 and 3.5). Area ratio of 1.5 (i.e., outlet/inlet, 0.75 m/0.50 m) exhibited the highest power coefficient Cp of 4.2, in addition to achieving highest resulting velocity of 25.8 m/s under incident velocity of 16m/s. Considerable wind separation inside inner walls of diffusers occurred from area ratio 1.75 onwards, which impacted resulting velocities. Simulations performed with ANSYS CFD Academic to standalone diffusers. A series of incident velocities employed from 1 to 16 m/s that resulted in velocity increase by 120–156% respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.