Abstract

The purpose of the study was to examine the effects of bulb suctioning on healthy, term newborns and the feasibility of conducting a large‐scale study of this practice. In a randomized, controlled two‐group design pilot study, 10 newborns received oronasopharyngeal bulb suctioning at birth and 10 did not. Differences in Apgar scores, heart rates, and oxygen saturation levels were determined. Infants were randomized to groups before delivery. The participants were 20 term, healthy newborns of uncomplicated pregnancies. Apgar scores, heart rates, and oxygen saturation levels in the first 20 minutes of life were the main outcome variables. There were no statistically significant differences in Apgar scores between groups. Apgar scores at 5 and 10 minutes were 9 or 10 for all newborns. Newborns receiving bulb suctioning showed a statistically significant, lower heart rate (P = .042) during the first 20 minutes and a significantly higher SpO2 level (P = .005) by 15 minutes of age. Although statistically significant, these findings were not considered clinically significant because values remained within normal parameters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.