Abstract

A mathematical model for structural behavior of timber columns under fire has been proposed. The semi-analytical study has been carried out for evaluating the load-carrying capacity of timber columns exposed to fire. Particular emphasis has been given to critical buckling loads. For this purpose, a parametric study has been performed by which the influence of slenderness ratio, load level, and water content on critical buckling loads of timber columns have been investigated. The results of this preliminary study showed that the present semi-analytical method is conservative compared to the two simplified calculation methods offered by Eurocode 5 if the transfer of water is neglected, while, on the other hand, the results agree well for a water content of 12%. Moreover, for higher water contents, the present semi-analytical model is non-conservative compared to the Eurocode 5 methods.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.