As the scale of residual oil treatment increases and cleaner production improves in China, slurry bubble column reactors face many challenges and opportunities for residual oil hydrogenation technology. The internals development is critical to adapt the long-term stable operation. In this paper, the volumetric mass transfer coefficient, gas holdup and bubble size in a gas–liquid up-flow column are studied with two kinds of internals. The gas holdup and volumetric mass transfer coefficient increase by 120% and 42% when the fractal dimension of bubbles increases from 0.56 to 2.56, respectively. The enhanced mass transfer processing may improve the coke suppression ability in the slurry reactor for residual oil treatment. The results can be useful for the exploration of reacting conditions, scale-up strategies, and oil adaptability. This work is valuable for the design of reactor systems and technological processes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.