Abstract

Bubble nucleation and growth in the evaporator, condenser, upcomers, and feedwater distribution systems of open-cycle ocean thermal energy conversion (OTEC) power plants are examined. The phenomenon that will probably have the most impact on system design is cavitation in the warm water feed near the entrance of the evaporator. The critical bubble size for cavitation is about 105 μm. Sources of bubbles in the warm water feed are those entering from the ocean, those nucleating on suspended particles, and those nucleating on the upcomer wall. Analyses of bubble growth induced by changes in hydrostatic pressure, mass transfer, and coalescence are presented. Using available information for bubble size distribution in seawater at California locations, it is shown that cavitation will probably have a significant impact on evaporator performance unless a debubbler is provided upstream of the evaporator entrance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.