BTEX compounds can cause a threat to environment and human health. For this reason measurement devices are needed for rapid identification of such pollutants. The paper presents the results of recognition of mixtures of benzene, toluene, ethylbenzene and xylenes in humid air by means of two gas sensor arrays and linear discriminant analysis. Measurements were conducted during stabilization/solidification processes of contaminated soils. High classification ratios were obtained for both arrays (I: 88%–94%; II: 94%–96%). Improvement of identification was achieved when two copies of every sensor were included in analysis – classification rates reached 97.1–100%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.