Abstract

Background: There are rare reports of broken surgical blades occurring during lumbar discectomy, and even fewer that discuss their retrieval.Case Description: While a 54-year-old male was undergoing a lumbar discectomy, the knife blade was broken. As it was difficult to retrieve the fragment through the original incision, the patient was closed, and a postoperative angio-computerized tomography (CT) was obtained. When the CT angiogram (CTA) documented the retained fragment had become lodged near the iliac vein within the psoas muscle, a second operation for blade retrieval, consisting of a paravertebral, lateral transpsoas approach, was successfully performed.Conclusion: In some cases, it is difficult to retrieve a broken scalpel blade during the index surgery. When this occurs, we would recommend closing the patient, and obtaining a CTA to better document the location of the retained foreign body. Based upon these findings, a safer second stage procedure may be performed (e.g., as in this case using a paravertebral lateral transpsoas approach) to avoid undue sequelae/morbidity.