Abstract

It is shown that the line width of conducting layers can be computed from simple d‐c electrical measurements made on bridge and van der Pauw shaped test structures. A compact six‐contact, cross‐bridge sheet resistor test structure was developed to make this measurement directly. Line widths measured on boron nitride diffused layers indicate that the method is sensitive to width variations of the order of ±0.1 μm (±4 μin.)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.