Abstract

After gathering baseline data on TIAE, an interdisciplinary team underwent a mini-Delphi process to identify key drivers for decreasing severe TIAE rates. We launched a 4-part airway safety bundle that included: (1) color-coded weight-based equipment chart, (2) visual schematic of airway equipment, (3) recommended medication dosing, and (4) safety checklist across a single, tertiary PED and 5 satellite community PUCs/PEDs. Multiple plan-do-study-act cycles were undertaken, and results were monitored using statistical process control charts. Charts were restaged when special cause variation was achieved. This study aimed to decrease the severe TIAE rate from a baseline of 23% in the tertiary site and 25% in the community sites to <15% within 12 months and to sustain these outcomes for 6 months. During the study period, we noted decreased rates of severe TIAE in both the PED and PUC setting during the intervention period, and we have sustained this improvement for more than 6 months in all sites with no associated change in balancing measures. Implementation of an airway safety bundle over a wide geographic area and among personnel with variable levels of training is possible and has the potential to decrease severe TIAE across multiple clinical settings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.