Abstract

Isoflurane is a commonly used inhaled anesthetic that can be adjusted for level of anesthetic depth and offers a rapid recovery for both clinical settings and laboratory animal research. Initial studies in our laboratory indicated no difference in PaCO2 (36.7±2.4 vs. 34.8±2.6 mmHg) or pH (7.43±0.02 vs. 7.43±0.02) between conscious (NO ISO) and 1% isoflurane (ISO) exposed CD‐1 mice. Our purpose was to investigate if arterial blood sampling with 1% ISO is a suitable alternative to conscious sampling for monitoring ventilation in a commonly studied mouse strain. This study aimed to test the hypothesis that breathing patterns and blood pressure in conscious and lightly isoflurane anesthetized B6/C57 mice are similar. At 3 months of age, 8 male B6/C57 mice (27.5±1.9 g body weight; MEAN±SD) underwent whole body unrestrained barometric plethysmography to quantify the pattern of breathing. Mice were tested during the light cycle with an isoflurane vaporizer preceding the animal chamber and a vacuum following the chamber (100 mL/min) to prevent accumulation of ISO. After a 30 min acclimation period with air (20.93% O2, balanced N2), mice were exposed to 5 minutes of the following: 2% ISO/air, 1% ISO/air, 1% ISO/10% O2 (hypoxia),1% ISO/air, 1% ISO/5% CO2 (hypercapnia); the last minute of each gas exposure was analyzed with Ponemah™ software. The same mice were administered these gas exposures without ISO (NO ISO) a week later; quiet baseline breathing was considered during this exposure as the 5 minutes when mice were not moving or sniffing in the cage. Breathing frequency (F; breaths/min), tidal volume (TV; mL/breath), and minute ventilation (MV; mL/min) were quantified; NO ISO vs. 1% ISO (MEAN±SD; *=p<0.05) shown in the following text. Quiet breathing compared to 1%ISO/air was not different for F: 185±30 vs. 168±31, TV: 0.29±0.04 vs. 0.31±0.16, or MV: 57.5±10.6 vs. 52.6±26.4. A blunted hypoxic response resulted with ISO; this was due to a lower F and MV (F: 265±31 vs. *176±22, TV: 0.41±0.07 vs. 0.39±0.14, MV: 123.8±27.1 vs. *72.3±29.9). Hypercapnia also resulted in a reduced response to ISO with F, TV and MV differences (F: 352±28 vs. *157±23, TV: 0.63±0.07 vs. *0.43±0.21, MV: 237.1±53.7 vs. *72.6±45.3). Conscious and 1% ISO arterial blood sampling in B6/C57 mice showed no difference in PaCO2 (38.8±1.9 vs. 35.2±2.3 mmHg), but differences did emerge with pH (7.43±0.02 vs. *7.38±0.03). Additional experiments were conducted to measure blood pressure with the volume‐pressure recording tail cuff method to determine other possible systemic changes with ISO, but no differences were uncovered (96±8 vs. 85±11 mmHg) although the data did approach significance. These experiments demonstrate the pattern of quiet breathing, ventilation and blood pressure are similar in conscious and 1% ISO exposed mice. However, the capacity to respond to respiratory stressors is attenuated with 1% ISO. Overall due to the near significant p‐values, along with clear differences from hypoxia/hypercapnia, we do not recommend blood sampling with 1% ISO as an alternative to monitoring conscious ventilation.Support or Funding InformationFunded by 1 R15 HD076379‐01A1, AML supported by McDevitt Fellowship, CNR supported by 1 R15 HD076379‐01A1S1.This abstract is from the Experimental Biology 2018 Meeting. There is no full text article associated with this abstract published in The FASEB Journal.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.