Abstract

Healthcare systems all over the world have been enormously affected by the COVID-19 pandemic. Healthcare workers (HCWs) taking care of these patients need personal protective equipments (PPEs) standardized for full protection from droplets and aerosols carrying viral load to variable distances. There has been a surge of manufacturers supplying these protective gears in India and regulatory agencies have issued technical specifications pertaining to PPEs focusing solely on synthetic blood penetration tests (SBPTs) and keeping the upper limit of non-woven fabric to 95 g/m2 (GSM). These PPE specifications are silent on air permeability (AP) and water/moisture vapor transmission rate (WVTR/MVTR) of the fabric. As a result, most of the PPE kits, despite having appropriate SBPT certifications from regulatory agencies, have extremely poor permeability and breathability. The acceptability of PPEs by HCWs can be vastly improved when the end-users are proactively invited to participate in “comfort testing” of PPEs before getting issuance of certification for marketing. “Field testing” or “end-user trials” in which HCWs don the PPE and assess it for comfort while performing different types of clinical work, e.g., in intensive care units (ICUs), operation theaters, cath labs, etc., also takes into account a hitherto often ignored “human-comfort-factor” that not only enhances the understanding of HCWs about the need for the PPEs but can also motivate them to use it without worrying about discomfort. We hereby propose that comfort fit testing (COmfort and Material Fit is an Obviously Required Test) should be a part of the mandatory testing and certification process for PPE, so that the industry invests wisely in manufacturing PPE kits that are not only certified for fabric but are also tested for comfort factors.How to cite this article: Kapoor A, Baronia AK, Azim A, Agarwal G, Prasad N, Mishra R, et al. Breathability and Safety Testing of Personal Protective Equipment: “Human-comfort” Factor Remains Undefined. Indian J Crit Care Med 2021;25(1):12–15.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.