SummaryBreath hydrogen production after oral lactose loading was examined in infants and children with stagnant loop syndrome, blind loop syndrome, or both. All six infants under 3 years of age had bacteriological evidence of small intestinal colonization. The characteristics of the breath hydrogen test in this syndrome are: (a) extremely high basal excretion of breath hydrogen (after overnight fasting); (b) an earlier and greater breath hydrogen value (0.293 ± 0.201 ml/min/m2: mean ± SD) after oral lactose administration than formed in lactose malabsorption alone (0.050 ± 0.041 ml/min/m2); and (c) the observation of a sustained hydrogen rise over several hours. This investigation demonstrated that the breath hydrogen test is a promising and noninvasive tool for diagnosing blind (or stagnant) loop syndrome.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.