Abstract

BackgroundVibro-acoustography (VA) is a newly developed imaging technology that is based on low-frequency vibrations induced in the object by the radiation force of ultrasound. VA is sensitive to the dynamic characteristics of tissue. Here, we evaluate the performance of VA in identifying benign lesions and compare the results to those of mammography.MethodsAn integrated mammography-VA system designed for in vivo breast imaging was tested on a group of female volunteers, age ≥ 18 years, with suspected breast lesions based on clinical examination. A set of VA scans was acquired after each corresponding mammography. Most lesions were classified as benign based on their histological results. However, in 4 cases, initial diagnosis based on clinical imaging determined that the lesions were cysts. These cysts were aspirated with needle aspiration and disappeared completely under direct ultrasound visualization. Therefore, no biopsies were performed on these cases and lesions were classified as benign based on clinical findings per clinical standards. To define the VA characteristics of benign breast masses, we adopted the features that are normally attributed to such masses in mammography. In a blinded assessment, three radiologists evaluated the VA images independently. The diagnostic accuracy of VA for detection of benign lesions was assessed by comparing the reviewers’ evaluations with clinical data.ResultsOut of a total 29 benign lesions in the group, the reviewers were able to locate all lesions on VA images and mammography, 100% with (95% confidence interval (CI): 88% to 100%). Two reviewers were also able to correctly classify 83% (95% CI: 65% to 92%), and the third reviewer 86% (95% CI: 65% to 95%) of lesions, as benign on VA images and 86% (95% CI: 69% to 95%) on mammography.ConclusionsThe results suggest that the mammographic characteristics of benign lesion may also be used to identify such lesions in VA. Furthermore, the results show the ability of VA to detect benign breast abnormalities with a performance comparable to mammography. Therefore, the VA technology has the potential to be utilized as a complementary tool for breast imaging applications. Additional studies are needed to compare the capabilities of VA and traditional ultrasound imaging.

Highlights

  • Vibro-acoustography (VA) is a newly developed imaging technology that is based on low-frequency vibrations induced in the object by the radiation force of ultrasound

  • Two participants were excluded from the study because of accidental hardware failure that occurred during the study

  • Women volunteers with abnormality in their clinical breast examination and/or mammography BI-RADS category 4 or less were included in this study

Read more

Summary

Introduction

Vibro-acoustography (VA) is a newly developed imaging technology that is based on low-frequency vibrations induced in the object by the radiation force of ultrasound. Any imaging evaluation of the breast with high sensitivity may be associated with increased false positive results that may leads to unnecessary (i.e. benign) biopsies, resulting in high cost as well as significant trauma and anxiety for the patients due to this invasive procedure and in some instances, they may choose unnecessary extensive varieties of surgeries such as mastectomy [6,7]. Alizad et al BMC Medical Imaging (2014) 14:40 accurate identification of benign non-proliferative conditions such as cysts and fibroadenomas can reduce unwanted benign breast biopsies. It is, important to develop imaging tools with higher specificity to reduce false positive test results.

Objectives
Methods
Results
Discussion
Conclusion