Abstract

Mammography, scintimammography and ultrasound images have been used to increase the specificity of breast cancer image diagnosis. Concerning breast cancer image diagnosis with ultrasound, some results found in the literature show better performance of morphological features in breast cancer lesion differentiation and that a reduced set of features shows a better performance than a large set of features. In this study we evaluated the performance of neural network classifiers, with different training stop criteria: mean square error, early stop and regularization. The last two criteria were developed to improve neural network generalization. Different sets of morphological features were used as neural network inputs. Training sets comprised of 22, 8, 7, 6, 5 and 4 features were employed. To select reduced sets of features, a scalar selection technique with correlation was used. The best results obtained for accuracy and area under the ROC curve were 96.98% and 0.98, respectively. The performance obtained with all 22 features is slightly better than the one obtained with a reduced set of features.