Abstract

Background parenchymal enhancement (BPE) is assessed on breast MRI reports as mandated by the Breast Imaging Reporting and Data System (BI-RADS) but is prone to inter and intrareader variation. Semiautomated and fully automated BPE assessment tools have been developed but none has surpassed radiologist BPE designations. To develop a deep learning model for automated BPE classification and to compare its performance with current standard-of-care radiology report BPE designations. Retrospective. Consecutive high-risk patients (i.e. >20% lifetime risk of breast cancer) who underwent contrast-enhanced screening breast MRI from October 2013 to January 2019. The study included 5224 breast MRIs, divided into 3998 training, 444 validation, and 782 testing exams. On radiology reports, 1286 exams were categorized as high BPE (i.e., marked or moderate) and 3938 as low BPE (i.e., mild or minimal). A 1.5 T or 3T system; one precontrast and three postcontrast phases of fat-saturated T1-weighted dynamic contrast-enhanced imaging. Breast MRIs were used to develop two deep learning models (Slab artificial intelligence (AI); maximum intensity projection [MIP] AI) for BPE categorization using radiology report BPE labels. Models were tested on a heldout test sets using radiology report BPE and three-reader averaged consensus as the reference standards. Model performance was assessed using receiver operating characteristic curve analysis. Associations between high BPE and BI-RADS assessments were evaluated using McNemar's chi-square test (α*=0.025). The Slab AI model significantly outperformed the MIP AI model across the full test set (area under the curve of 0.84 vs. 0.79) using the radiology report reference standard. Using three-reader consensus BPE labels reference standard, our AI model significantly outperformed radiology report BPE labels. Finally, the AI model was significantly more likely than the radiologist to assign "high BPE" to suspicious breast MRIs and significantly less likely than the radiologist to assign "high BPE" to negative breast MRIs. Fully automated BPE assessments for breast MRIs could be more accurate than BPE assessments from radiology reports. 4 TECHNICAL EFFICACY STAGE: 3.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.