Abstract

The paper describes the breakthrough microleaks-no-burst (μLNB) safety technology of explosion free in fire self-venting hydrogen tanks that do not require thermally-activate pressure relief devices (TPRD). The technology implies melting of the hydrogen-tight liner before hydrogen-leaky double-composite wall loses its load-bearing ability. Hydrogen then flows through the wall's microchannels and either burns in microflames on its own or together with resin. The experimental validation of the technology is presented for 7 prototypes with the nominal working pressure of 70 MPa made of carbon-carbon or carbon-glass composites. The prototypes are fire tested at the specific heat release rate HRR/A = 1 MW/m2 characteristic for gasoline/diesel spill fires. The μLNB technology eliminates catastrophic consequences of tank rupture in fire: blast waves, fireballs, and projectiles. The technology limits hydrogen accumulation in naturally ventilated enclosures. It reduces the risk of hydrogen-powered vehicles to an acceptable level below that for fossil fuel automobiles, including underground parking and tunnels. It provides an unprecedented level of life safety and property protection.