Breakdown strength is an important electrical property of insulating paper. Oil-impregnated paper of various aging states was prepared. Its breakdown voltage was then measured at pulsating direct current (DC) voltage with various ripple factors, and alternating current (AC) and DC voltage for comparison, respectively. The AC breakdown voltage is the smallest, and pulsating DC (r = 1/5) breakdown voltage is the greatest before the paper reaches its end of life. A dielectric model was adopted to investigate the difference in magnitude of breakdown voltage at different voltage waveforms. Meanwhile, it was found that breakdown voltage fluctuated and even increased occasionally during the thermal aging process, and a somewhat opposite changing tendency versus aging time was observed for breakdown voltage at DC voltage and pulsating DC voltage with small ripple factors (r = 1/5 and 1/3), compared with AC voltage. The degree of polymerization (DP) and moisture content of the paper were measured, and the characteristics of the pores and cracks of the paper were obtained to investigate the possible influencing factors of breakdown voltage at different aging states. The results showed that the moisture content, oil absorption ability associated with pores and cracks of paper, and the damage to paper structure all contributed to the variation of the breakdown voltage versus aging time, while the importance of their influence differed as the aging state of paper varied.

Highlights

  • Power transformers are essential to power transmission networks [1]

  • oil-impregnated paper (OIP) using its dielectric and physicochemical characteristics is essential to the safe operation, planned maintenance, and replacement of transformers [4]

  • Breakdown voltage is an important property of insulating paper, and thermal aging is the main form of OIP aging

Read more

Summary

Introduction

As the insulating medium of power transformers, oil-impregnated paper (OIP) degrades under interaction with heat, moisture, oxygen, and acids [2,3]. Among those aging factors, heat is the main cause of insulation aging, and reduces its mechanical strength and electrical performance. Condition assessment of OIP using its dielectric and physicochemical characteristics is essential to the safe operation, planned maintenance, and replacement of transformers [4]. Breakdown voltage is an important property of insulating paper, and thermal aging is the main form of OIP aging. Investigation into the breakdown characteristics of thermally aged OIP is conducive to understanding the influencing mechanism of aging on its insulating performance

Objectives
Methods
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call