The influence of the nitrogen pressure on the breakdown voltage in a nonuniform electric field is studied. Voltage pulses with nanosecond and subnanosecond rise times are applied to the gas gap. Simultaneously with the application of voltage pulses, supershort avalanche electron beam pulses are observed behind a foil anode. It is found that, when a runaway electron beam is generated and voltage pulses have a subnano-second rise time, the breakdown voltage rises as the nitrogen pressure decreases from 9 × 104 to 1 × 102 Pa. Experimental data are in good agreement with pulsed breakdown analytical curves.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.