Abstract

RF Breakdown in strong magnetic fields has a negative impact on a cavity performance. The MuCool Test Area at Fermilab has unique capabilities that that allow us to study the eects of static magnetic field on RF cavity operation. We have tested an 805 MHz pillbox-like cavity in external magnetic fields up to 5 T. Results confirm our basic model of breakdown in strong magnetic fields. We have measured maximum achievable surface gradient dependence on external static magnetic field. Damage inspection of cavity walls revealed a unique observed breakdown pattern. We present the analysis of breakdown damage distribution and propose the hypothesis to explain certain features of this distribution.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.