Abstract

Four types of brazes were used to join sheets of GLIDCOP™ Al25. Miniature tensile specimens were fabricated from the joints and irradiated under various conditions for a study of their response to high temperature neutron irradiation in FFTF Two of the sets of specimens, brazed with TiCuAg and TiCuNi, were found to possess low quality joints because of excessive diffusion of silver into the base metal in the case of the TiCuAg, and melting of the base metal in the case of the TiCuNi. Joints produced with a CuAu braze were satisfactory for the unirradiated state, but transmutation of Au to Hg affected the integrity of the joints irradiated in a below-core position where the transmutation rate per dpa was rather high. A CuAg braze yielded satisfactory joints in the unirradiated state and held up well when the irradiated specimens were tested. However, transmutation of Ag to Cd leads to a high residual radioactivity that may limit the usefulness of this braze after exposure to neutron irradiation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.