Abstract
Volar plate fixation of unstable distal radius fractures has become the preferred technique by most surgeons for the operative treatment of displaced distal radius fractures. Flexor tendon rupture is a rare but serious complication associated with this operation that is thought to be due to irritation of the flexor tendons over the prominent distal edge of the plate. We describe a novel technique of using the brachioradialis tendon to cover the distal edge of the plate to help prevent tendon irritation and rupture.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.