Abstract
Sternal retractors utilized during open-heart surgeries through median sternotomy can cause upper rib fractures which sometimes further leads to brachial plexus injury. We aimed to investigate the incidence of brachial plexus injury and upper rib fractures in open-heart surgeries and how these injuries are associated with each other. We investigated 1050 cases during the past five years. The incidence of brachial plexus injury and upper rib fractures after median sternotomy was assessed in all patients and the patients who sustained were evaluated for the affected side, the level of paralysis. Ten cases (0.95%) exhibited brachial plexus injury after median sternotomy. Nine cases developed paralysis on left upper extremity. In all ten cases, sensory and motor nerve impairment were exhibited in the lower plexus. Rib fractures were observed in 35.0% of cases after median sternotomy and the usage of asymmetric sternal retractors to harvest left internal thoracic artery (LITA) significantly affected the side of fracture. Sternal retractors utilized during open-heart surgeries through median sternotomy may cause rib fractures and brachial plexus injury, so operators should be aware of these complications.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.