Abstract

BackgroundBracing concepts in use today for the treatment of scoliosis include symmetric and asymmetric hard braces usually made of polyethylene (PE) and soft braces. A new asymmetric Chêneau style CAD/CAM derivate has been designed to overcome problems the author experienced with other Chêneau CAD/CAM systems over the recent years.Brace descriptionThis CAD/CAM Chêneau derivate has been called Gensingen brace™, a brace available to address all possible curve patterns. Once the patients' trunk is scanned with the help of a whole trunk optical 3D-scan and the patients' data from the clinical measurements are recorded, a model of the brace can be created by (1) modifying the trunk model of the patient 'on screen' to achieve a very individual brace model using the CAD/CAM tools provided or by (2) choosing a brace model from our library and re-size it to the patients' properties 'on screen'.ResultsEnd-result studies have been published on the Chêneau brace as early as 1985. Cohort studies on the Chêneau brace are available as is a prospective controlled study respecting the SRS criteria for bracing studies, demonstrating beneficial outcomes, when compared to the controls using a soft brace. Sufficient in-brace correction effects have been demonstrated to be achievable when the Chêneau principles of correction are used appropriately. As there is a positive correlation between in-brace correction and the final outcome, the Chêneau concept of bracing with sufficient in-brace corrections as published can be regarded as being efficient when applied well. Case reports with high in-brace corrections, as shown within this paper using the Gensingen brace™ promise beneficial outcomes when a good compliance can be achieved.ConclusionsThe use of the Gensingen brace™ leads to sufficient in-brace corrections, when compared to the correction effects achieved with other braces, as described in literature.According to the patients' reports, the Gensingen brace™ is comfortable to wear, when adjusted properly.Further studies are necessary (1) in order to evaluate brace comfort and (2) effectiveness using the SRS inclusion criteria.

Highlights

  • Case reports with high in-brace corrections, as shown within this paper using the Gensingen braceTM promise beneficial outcomes when a good compliance can be achieved

  • The use of the Gensingen braceTM leads to sufficient in-brace corrections, when compared to the correction effects achieved with other braces, as described in literature

  • Bracing concepts in use today for the treatment of scoliosis include symmetric and asymmetric hard braces usually made of PE on the one hand and soft braces on the other

Read more

Summary

Introduction

Bracing concepts in use today for the treatment of scoliosis include symmetric and asymmetric hard braces usually made of PE on the one hand and soft braces on the other. CAD (Computer Aided Design) systems are available, which allow brace adjustments without plaster Another new development is the ScoliOlogiCTM off the shelf system enabling the technician to construct a light brace for scoliosis correction from a variety of pattern specific shells to be connected to an anterior and a posterior upright [1]. This Chêneau lightTM brace, constructed according to the Chêneau principles using the brace parts from the ScoliOlogiCTM off the shelf system, promises a reduced impediment of quality of life in the brace. Once the patients’ trunk is scanned with the help of a whole trunk optical 3Dscan and the patients’ data from the clinical measurements are recorded, a model of the brace can be created by (1) modifying the trunk model of the patient ‘on screen’ to achieve a very individual brace model using the CAD/ CAM tools provided or by (2) choosing a brace model from our library and re-size it to the patients’ properties ‘on screen’

Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call