Abstract

A new methodology is described for determining the atmospheric emission rate of pollutants from large heterogeneous area sources, such as hazardous waste sites. The procedure hinges upon measuring average pollutant concentrations, at three or more different elevations, while traversing the plume downwind of the area source. A helium-filled tethersonde balloon is used to elevate the sampling lines to their appropriate height. During plume traversing the sampling rate is adjusted to be proportional to the sine of the angle between the wind vector and the direction of the traverse path. The average concentrations are corrected for any upwind, background concentration and then used to derive an average vertical concentration profile. This profile Is numerically integrated, with the wind velocity profile, over the pollutant boundary layer to yield the area source emission rate. The methodology was tested on several large industrial effluent lagoons and proved to be easy to use, robust, and precise.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.