AbstractThis paper presents a 3D theoretical simulation and analysis of DC stray current corrosion (SCC) in oil fields that could contribute to oil leak and finally oil deferment of electric submersible pump (ESP) systems. Application of the boundary element analysis system (BEASY) allowed cathodic protection (CP) interference to be assessed in terms of the normal current density, which is directly proportional to the corrosion rate, rather than using the qualitative approach of measuring the potential shift of the soil. Different real structures consisting of pipelines and/or well casings with different arrangements and interference conditions are simulated. The results reveal that the application of impressed current cathodic protection (ICCP) systems creates DC SCC on other nearby unprotected structures. This is an inherent potential problem with the application of such systems which dominates with decreasing soil conductivity, and/or increasing the anode current density and its proximity to the protected structures. On the contrary, SCC can be reduced by using multi‐groundbed anodes. Copyright © 2006 John Wiley & Sons, Ltd.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: European Transactions on Electrical Power
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.