Abstract

In this study, boron removal from synthetic solutions and boron mine wastewater by coagulation method using in-situ formed Al(OH)3 from AlCl3 salt was investigated. The experimental parameter for synthetic solution was solution pH. The optimum condition for synthetic boron solutions was determined as pH (8). The ideal pH value obtained from the synthetic solutions was applied to the boron mine wastewater with concentration of 373.19 mg L-1 by 21×21 full factorial experimental design. The parameters in the design were dosage of aluminium chloride (5, 10 g) and dilution factor (1,10 fold). The aluminium hydroxide provided maximum 100% removal from mine wastewater at optimum conditions. Also, the data obtained were analyzed by means of Pareto chart and surface plot. P values for all the parameters were found as above 95% confidence limit value (p

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.