Abstract

A polyvinyl alcohol (PVA)/polyethylene glycol (PEG)-based resin is commonly used as a cryoembedding medium for the histological analysis of frozen tissue sections. However, it is not easy to obtain sufficient numbers of satisfactory reproducible sections owing to the differences between the mechanical properties of the medium and embedded tissue and the low cohesive force of the medium. We describe a modified PVA-based cryoembedding medium, composed of PVA (10wt% and 15wt%) with the addition of boric acid (from 0 to 5wt%), that can improve the sectioning properties and efficiency of frozen tissue for histological analysis. The amount of load under the same compressive displacement as well as cohesive force increased with increasing boric acid and PVA contents. 15wt% PVA and 3wt% boric acid was determined as an optimal composition for cryoembedding material based on the sectioning efficiency measured by the numbers of unimpaired sectioned slices and the amount of load under the same compressive displacement test. On the basis of the results of routine hematoxylin and eosin staining of cryosections of tissue embedded in a medium with 3wt% boric acid and PVA, it was concluded that the modified PVA cryoembedding medium can improve the efficiency of cryosectioning for subsequent histological or histochemical analysis of various tissues.