Abstract
This study investigated a conservative femoral component for hip replacement surgery. Re-surfacing implants with two hydroxyapatite-coated pins were inserted into the right femoral necks of eight adult goats for one year. Radiographic analysis revealed bone loss directly beneath the prosthetic cup with increased amounts of bone at the distal end of the pins. Microscopic analysis revealed localised areas of bone formation adjacent to the implant. Oxytetracycline bone markers demonstrated significantly decreased bone formation rates (p<0.05) in bone adjacent to the implant in the operated compared to the control hips. Image analysis results demonstrated an average bone attachment of 30.94% to the implant surface. Attachment varied regionally, with greatest bone attachment at the end of the pins (78.99%) contributing 22% of total bone attachment to the implant. Least bone attachment (13.82%) was measured beneath the prosthetic cup and adjacent to the medial aspect of the pin. This contributed 4% of total bon...
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.