Abstract

Purpose: Osteoporosis is under-diagnosed and often co-exists with other diseases. Very low bone mineral density (BMD) indicates risk of osteoporosis and opportunistic screening for low BMD in CT-scans has been suggested. In a non-contrast enhanced thoracic CT scan, the scan-field-of-view includes vertebrae enabling BMD estimation. However, many CT scans are obtained by administration of contrast material. If the impact of contrast enhancement on BMD measurements could be quantified, considerably more patients are eligible for screening. Methods: This study investigated the impact of intravenous contrast on thoracic BMD measurements in cardiac CT scans pre- and post-contrast, including different contrast trigger levels of 130 and 180 Hounsfield units (HU). BMD was measured using quantitative CT with asynchronous calibration. Results: In 195 participants undergoing cardiac CT (mean age 57±9 years, 37 % females) contrast increased mean thoracic BMD from 116±33 mg/cm3 (non-enhanced CT) to 130±38 mg/cm3 (contrast-enhanced CT) (p<0.001). Using clinical cut-off values for very low (<80 mg/cm3) and low BMD (<120 mg/cm3) showed that 24 % (47/195 participants) were misclassified when BMD was measured on contrast-enhanced CT-scans. Of the misclassified patients, 6 % (12/195 participants) were categorized as having low BMD despite having very low BMD on the non-enhanced images. Contrast-CT using a higher contrast trigger level showed a significant increase in BMD compared to the lower trigger level (119±32 vs. 135±40 mg/cm3, p<0.01). Conclusion: For patients undergoing cardiac CT, using contrast-enhanced images to assess BMD entails substantial overestimation. Contrast protocol trigger levels also affect BMD measurements. Adjusting for these factors is needed before contrast-enhanced images can be used clinically. Mini abstract: Osteoporosis is under-diagnosed. Contrast-enhanced CT made to examine other diseases might be utilized simultaneously for bone mineral density (BMD) screening. These scans, however, likely entails overestimation of BMD due to the effect of contrast. Adjusting for this effect is needed before contrast-enhanced images can be implemented clinically for BMD screening.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.